System Error Code: 16.03:00 – Curing system: high temperature error
ON: HP Latex 310,315,330,335,360,365 and 560 Designjet Printer
Problem description:
Ambient temperature above 30oC, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature
Sensor, Curing Pressure Sensor.
Corrective action:
Service engineer:
1. The environmental ambient temperature is too hot or is outside the operational specification of the
printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters
etc.
2. Run Service "Curing system monitor”.
3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
4. Reseat/Replace Curing Resistors.
5. Reseat/Replace Curing Temperature Sensors.
6. Reseat/Replace Curing Pressure Sensor.
Book call out: <Click Here>